The engine-ECU learns the relation between the suction control valve (linear solenoid
valve) of the supply pump drive current and the fuel injection volume.
|
|
The learning value is calculated from the suction control valve drive current and the
rail pressure sensor output voltage.
|
|
When the supply pump is replaced, therefore, this learning must be executed.
|
|
Re-learning is executed when the engine is idling after the learning value in the engine-ECU
has been reset by the M.U.T.-III.
|
|
1.After the ignition switch is in "LOCK" (OFF) position, connect the M.U.T.-III to the
diagnosis connector.
|
|
2.Turn the ignition switch to "ON" position. (Do not start the engine.)
|
|
3.Select SPECIAL FUNCTION from the function menu.
|
|
4.Select SUPPLY PUMP CORRECTION LEARNING from the SPECIAL FUNCTION menu and execute
the initializing of the learning value.
|
|
5.After initializing, run the engine at idle in the following conditions.
- Accelerator pedal: OFF
- Engine coolant temperature: 60°C or higher
- Fuel temperature: 30°C or higher
|
|
6.Confirm that the item No. 65 High pressure pump learned status on M.U.T.-III Service
Data is "2".
|