1.Connect a manual pump (pressure-application type) to nipple.
caution |
In order to avoid damage to the diaphragm, do not apply a pressure
of 159 kPa or higher.
|
2.While gradually applying pressure, check the pressure that begins to activate (approximately
1 mm stroke) the waste gate actuator rod. Standard value: 125.3 - 135.7 kPa3.If there is a significant deviation from the standard value, check the actuator or
the waste gate valve: replace actuator or turbocharger assembly if necessary.
|