CENTRE DIFFERENTIAL LOCK DETECTION SWITCH CHECK



Check the continuity between terminals of the brown connector indicated in the illustration.
Transfer lever position
Specified condition
4HLc and 4LLc
Continuity (Less than 2 Ω)
2H and 4H
Open circuit