Code No.B1519: SRS-ECU connector lock out of order




DIAGNOSIS CODE SET CONDITIONS


This diagnosis code is set if a poor connection at the SRS-ECU is detected.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Connector lock check: SRS-ECU connectors C-130 and C-131. (M.U.T.-III diagnosis code)


(1)Disconnect the negative battery terminal.

(2)Disconnect SRS-ECU connectors C-130, C-131 and then reconnect them.
(3)Connect the negative battery terminal.
(4)Erase diagnosis code memory, and then check the diagnosis code.

Q. Is diagnosis code B1519 set?

Go to Step 2.

The procedure is complete. It is assumed that diagnosis code B1519 set as connectors C-130 and C-131 were engaged improperly.

STEP 2. Connector lock check: SRS-ECU connectors C-130 and C-131.




(1)Disconnect SRS-ECU connectors C-130 and C-131.
(2)Check the connector lock switch terminal inside the harness side connector for improper contact or deformation.

Q. Are the SRS-ECU connectors C-130 and C-131 in good condition?

Go to Step 3.

Repair the SRS-ECU connector C-130 and C-131.

STEP 3. Check whether the diagnosis code is reset.


Q. Is diagnosis code B1519 set?

Replace the SRS-ECU (Refer to ).
An intermittent malfunction is suspected (Refer to GROUP 00, How to Cope with Intermittent Malfunction ).