DIAGNOSIS PROCEDURE |
STEP 1. Check the harness for open circuit to earth between SRS-ECU connector C-131 (terminal No.8) and combination meter connector C-113 (terminal No.18). |
STEP 2. Check whether the diagnosis code is reset. |
Q.
Is diagnosis code B1551 set?
|
Replace the SRS-ECU (Refer to ). |
|
An intermittent malfunction is suspected (Refer to GROUP 00, How to Cope with Intermittent Malfunction ). |
|