When the turn-signal lamp switch is operated, check that the turn-signal lamps illuminate/go off normally.
|
|
Q.
Are the turn-signal lamps in good condition?
|
|
First, repair the turn-signal lamps. Refer to trouble symptom chart .
|
|
|
|
Q.
Is the check result normal?
Go to Step 3.
Repair the defective connector.
|
|
(1)Disconnect the connector, and measure at the wiring harness side.
|
|
(2)Check the resistance between the lamp connector and body earth. Resistance between C-111 combination meter connector terminal No.57 and body earth OK: Continuity exists (2 Ω or less)
Q.
Is the check result normal?
Go to Step 5.
Go to Step 4.
|
|
- Check the earth wires for open circuit.
Q.
Is the check result normal?
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
Repair the wiring harness.
|
|
Q.
Is the check result normal?
Go to Step 6.
Repair the defective connector.
|
|
note |
Prior to the wiring harness inspection, check junction block connector C-210 and intermediate connector C-54 <L.H. drive vehicles> or C-14 <R.H. drive vehicles>, and repair if necessary.
|
- Check the output lines for open circuit.
Q.
Is the check result normal?
Go to Step 7.
Repair the wiring harness.
|
|
Check that the turn-signal lamp indicator illuminates normally.
|
|
Q.
Is the check result normal?
|
|
The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).
|
|
|
|
Replace the combination meter.
|
|
|