Code No.U1500: Column-ECU Time-out






TROUBLE JUDGMENT


The ETACS-ECU receives signal from the column-ECU. If signal cannot be received at all, diagnosis code No.U1500 will be set.

COMMENT ON TROUBLE SYMPTOM


The M.U.T.-III shows a diagnosis code status as active.
The M.U.T.-III shows a diagnosis code status as stored.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Connector check: C-219 ETACS-ECU connector, C-302 column switch connector






Q. Is the check result normal?

Go to Step 2.

Repair the defective connector. Go to Step 3.

STEP 2. Check the wiring harness between C-219 ETACS-ECU connector terminal No.54 and C-302 column switch connector terminal No.3.







  • Check the communication line for open circuit.

Q. Is the check result normal?

Go to Step 3.

Repair the wiring harness. Go to Step 3.

STEP 3. Check whether the diagnosis code is reset.


Check again if the diagnosis code is set to the ETACS-ECU.
(1)Erase the diagnosis code.
(2)Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
(3)On completion, check that the diagnosis code is reset.

Q. Is the check result normal?

A poor connection, open circuit or other intermittent malfunction is present in the LIN bus lines between the column-ECU and the ETACS-ECU (Refer to GROUP 00, How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions ).
Replace the column-ECU.