INSPECTION



A/C TEMPERATURE CONTROL RESISTOR CHECK




STANDARD VALUE:
Measurement terminal
Standard value (Ω)
Between terminal Nos. 1 and 4
2.54
Between terminal Nos. 1 and 3
1.24
Between terminal Nos. 1 and 2
0.60

BLOWER FAN AND MOTOR CHECK



Check that the motor turns when applying battery power between the connector terminals. Also check to see that there is no abnormal sound emitted from the motor at this time.