Lift the claw, and remove the air selection lever knob.
|
|
Always remove the cable by pressing the clip.
note |
When removing the cable, make sure that the sleeve does not become misaligned.
|
|
|
1.Set the Temperature control dial of the heater control assembly to MAX HOT position.
|
|
2.Turn the air mixing damper lever of heater unit to the MAX HOT position (Turn the damper
lever to the left until it stops.) and then install the cable. 3.Install the cable to the clip and fix it while aligning the case.
note |
When installing the cable to the case, make sure that the sleeve does not become misaligned.
|
|
|
1.Set the mode selection dial of the heater control assembly to FOOT position.
|
|
2.Turn the air outlet changeover damper lever of heater unit to the DEF position (Turn the
damper lever to the left until it stops.) and then install the cable. 3.Install the cable to the clip and fix it while aligning the case.
note |
When installing the cable to the case, make sure that the sleeve does not become misaligned.
|
|
|
1.Set the air selection lever on the heater control panel assembly to the inside recirculation.
|
|
2.Set the outside/Inside air selection damper lever of the heater blower assembly
to the inside position as shown in the illustration, and then connect the cable to the link
pin. 3.Install the cable to the clip and fix it while aligning the case.
note |
When installing the cable to the case, make sure that the sleeve does not become misaligned.
|
|