RELAY CONTINUITY CHECK



A/C COMPRESSOR RELAY CONTINUITY CHECK



Battery voltage
Tester connection
Specified condition
Not applied
3 - 4
Open circuit

  • Connect terminal 1 to the positive battery terminal
  • Connect terminal 2 to the negative battery terminal

3 - 4
Continuity (Less than 2Ω)

CONDENSER FAN RELAY CONTINUITY CHECK



Battery voltage
Tester connection
Specified condition
Not applied
3 - 4
Open circuit

  • Connect terminal 1 to the positive battery terminal
  • Connect terminal 2 to the negative battery terminal

3 - 4
Continuity (Less than 2Ω)

PTC HEATER RELAY CONTINUITY CHECK



Battery voltage
Tester connection
Specified condition
Not applied
1 - 3
Open circuit

  • Connect terminal 2 to the positive battery terminal
  • Connect terminal 4 to the negative battery terminal

1 - 3
Continuity (Less than 2Ω)

BLOWER RELAY CONTINUITY CHECK




Battery voltage
Tester connection
Specified condition
Not applied
3 - 4
Open circuit

  • Connect terminal 1 to the positive battery terminal
  • Connect terminal 2 to the negative battery terminal

3 - 4
Continuity (Less than 2Ω)