1.Use the M.U.T.-III to measure the A/T fluid temperature and check that the A/T fluid
temperature is 20°C.
|
|
2.Disconnect the A/T control solenoid valve assembly connector. 3.Measure the resistance between the solenoid valve terminals. 4.Check that the measured values are within the standard values at items 1 and 3.
|
STANDARD VALUE:
Name
|
Terminal No.
|
Resistance value
|
Damper clutch control solenoid valve
|
7 - 10
|
2.7 - 3.4 Ω (A/T fluid temperature
20°C)
|
Low-reverse solenoid valve
|
6 - 10
|
Second solenoid valve
|
4 - 9
|
Underdrive solenoid valve
|
3 - 9
|
Overdrive solenoid valve
|
5 - 9
|
Reduction solenoid valve <5A/T>
|
8 - 10
|
|
5.If within the standard value, check the power supply and the earth circuits. 6.If not within the standard value, drain the A/T fluid and remove the valve body cover.
|
|
7.Disconnect the solenoid valve connectors.
|
|
8.Measure the resistance between terminals 1 and 2 at each solenoid valve side. Standard value: 2.7 - 3.4 Ω (A/T fluid temperature 20°C) 9.If not within the standard value, replace the solenoid valve. 10.If within the standard value, check the harness wire between A/T control
solenoid valve assembly connector and each solenoid valve connector. If a problem is not found
at the steps above, check the solenoid valve O-rings and replace if necessary.
|