Code No.
|
Diagnostic item
|
Reference page
|
Service data display contents when diagnosis code is set
|
B1001
|
Interior temperature sensor system (short circuit)
|
|
25°C
|
B1002
|
Interior temperature sensor system (open circuit)
|
|
B1011
|
Ambient temperature sensor system (short circuit)
|
|
20°C
|
B1012
|
Ambient temperature sensor system (open circuit)
|
|
B1021
|
Air thermo sensor system (short circuit)
|
|
-6°C
|
B1022
|
Air thermo sensor system (open circuit)
|
|
B1041
|
Potentiometer system for the air mixing damper (short to power supply)
|
|
Moved to MAX HOT position
|
B1042
|
Potentiometer system for the air mixing damper (short to earth or
open circuit)
|
|
B1045
|
Motor drive system for the air mixing damper <LHD>
|
|
-
|
B1045
|
Motor drive system for the air mixing damper <RHD (Europe)>
|
|
-
|
B1061
|
Potentiometer system for mode selection damper (short to power supply)
|
|
Moved to DEF position
|
B1062
|
Potentiometer system for mode selection damper (short to earth or
open circuit)
|
|
B1065
|
Motor drive system for mode selection damper
|
|
-
|