caution |
|
INSTALLATION SERVICE POINTS |
>>A<< O-RING/MANIFOLD ABSOLUTE PRESSURE SENSOR/PURGE CONTROL SOLENOID VALVE INSTALLATION |
1.Apply a small amount of new engine oil to the O-ring. |
2.Install the manifold absolute pressure sensor and the purge control solenoid valve
to the inlet manifold with care not to damage the O-ring. |
3.
Tightening torque: 4.0 ± 1.0 N·m |
>>B<< THROTTLE BODY GASKET INSTALLATION |
Fit the throttle body gasket in the inlet manifold groove securely with neither twisting
nor damage given. |