Item No.
|
Inspection Item
|
Drive content
|
Inspection condition
|
Normal condition
|
Code No. or inspection procedure No.
|
Reference page
|
1
|
Injectors
|
Specified injector is stopped
|
Engine: warm up, idle (cut the fuel supply to each injector in turn and check cylinders which don’t affect idling.)
|
Idle condition is changed by stopping selected cylinder: this can cause an unstable condition and the engine may stall.
|
Code No. P0261, P0262, P0264, P0265, P0267, P0268, P0270, P0271
|
, , , , , , ,
|
9
|
Fuel pump
|
Drive fuel pump to circulate fuel
|
- Ignition switch: "ON"
- Check for pump operating noise near fuel tank
|
Operating noise audible
|
Procedure No. 20
|
|
10
|
Purge control solenoid valve
|
Switch solenoid valve from OFF to ON
|
Ignition switch: "ON"
|
When the valve is actuated, operating noise is audible
|
Code No. P0458, P0459
|
,
|
14
|
Cooling fan motor
|
Actuate the fan motor
|
Ignition switch: "ON"
|
Fan motor rotates at high speed
|
-
|
-
|
16
|
A/C compressor relay
|
Switch the A/C compressor relay from OFF to ON
|
Ignition switch: "ON"
|
The operating sound of A/C compressor is audible
|
Procedure No. 21
|
|
17
|
Inlet oil feeder control valve
|
Switch the inlet oil feeder control valve from OFF to ON
|
Ignition switch: "ON"
|
When the valve is actuated, operating noise is audible
|
Code No. P0010
|
|