COOLING FAN RELAY CONTINUITY CHECK <4B1, 4J1>




FAN CONTROL RELAY CHECK



Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
2 - 5
Continuity (Less than 2 Ω)
4 - 5
Open circuit
Connect terminal No. 3 and battery (+) terminal.
Connect terminal No. 1 and battery (-) terminal.
2 - 5
Open circuit
4 - 5
Continuity (Less than 2 Ω)

RADIATOR FAN RELAY CHECK



Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
2 - 4
Open circuit
Connect terminal No. 3 and battery (+) terminal.
Connect terminal No. 1 and battery (-) terminal.
Continuity (Less than 2 Ω)

CONDENSER FAN RELAY CHECK



Battery voltage
Terminal No. to be connected to tester
Continuity test results
Not applied
3 - 4
Open circuit
Connect terminal No.1 and battery (+) terminal.
Connect terminal No.2 and battery (-) terminal.
Continuity (Less than 2 Ω)