- Disconnect connector, and measure at harness side.
- Ignition switch: ON
- Voltage between terminal DCCT and earth.
|
|
Q.
Is the check result normal?
|
|
Q.
Is the check result normal?
|
|
Replace the DC/DC converter (entertainment system).
|
|
|
|
Repair the connector(s) or wiring harness.
|
|
|
|
- Measure the voltage AS&G-ECU connector terminal.
- Ignition switch: ON
- Voltage between terminal DCCT and earth.
|
|
OK: Voltage is 25% of the battery voltage or less.
|
|
Q.
Is the check result normal?
|
|
- Reconfirmation of the diagnosis code.
|
|
Q.
Is the diagnosis code set?
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions).
|
|
|
|
- Measure the voltage AS&G-ECU connector terminal.
|
|
- Perform auto start with the following procedures.
- Change vehicle status to auto stop status.
- Selector lever: D range → P range
- Release the brake pedal then depress it again (Auto Start carried out at this point).
|
|
- Voltage between terminal DCCP and earth.
|
|
OK: Voltage is 75% of the battery voltage or more.
|
|
Q.
Is the check result normal?
|
|
- Reconfirmation of the diagnosis code.
|
|
Q.
Is the diagnosis code set?
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions).
|
|
|
|
Q.
Is the check result normal?
|
|
Repair the connector(s) or wiring harness.
|
|
|
|
- Reconfirmation of the diagnosis code.
|
|
Q.
Is the diagnosis code set?
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points - How to Cope with Intermittent Malfunctions).
|
|
|