SERVICE SPECIFICATIONS



Item
Standard value
A/T fluid temperature sensor kΩ
at 10°C
Approx. 6.62
at 25°C
Approx. 3.51
at 80°C
Approx. 0.55
at 110°C
Approx. 0.25
Hydraulic pressure MPa
During idling
0.385 - 0.525
During stall
Approx. 1.53
Resistance of low clutch linear solenoid valve [at 20°C] Ω
Approx. 5.3
Resistance of lock-up and low-reverse brake linear solenoid valve [at 20°C] Ω
Approx. 5.3
Resistance of 2-6 brake linear solenoid valve [at 20°C] Ω
Approx. 5.3
Resistance of line pressure linear solenoid valve [at 20°C] Ω
Approx. 5.3
Resistance of 3-5 reverse clutch linear solenoid valve [at 20°C] Ω
Approx. 5.3
Resistance of high clutch linear solenoid valve [at 20°C] Ω
Approx. 5.3
Resistance of low-reverse brake shift solenoid valve [at 20°C] Ω
Approx. 28
Resistance of low clutch shift solenoid valve [at 20°C] Ω
Approx. 28
Shift lock solenoid resistance Ω
24 ± 1.2
Stall speed r/min
2,300 - 2,800
Opening temperature of thermo valve °C
75 ± 1.5
Full opening temperature of thermo valve °C
95 or more
Thermo valve amount when it is fully opened mm
3 or more