A/T FLUID TEMPERATURE SENSOR CHECK


1.Disconnect the A/T control solenoid valve assembly connector.

2.Measure the resistance between the sensor-side connector terminal No. 2 and 3 of the A/T control solenoid valve assembly connector.
Standard value:
Fluid temperature °C
Resistance kΩ
10
Approx. 6.62
25
Approx. 3.51
80
Approx. 0.55
110
Approx. 0.25
note In the information screen on the multi-information display, the fluid temperature warning comes on when the A/T fluid temperature is approximately 140°C or higher, and automatically goes out when the A/T fluid temperature dropped below approximately 135°C.
3.
caution The A/T fluid temperature sensor cannot be removed or replaced as a single unit. When the A/T fluid temperature sensor needs to be replaced, replace the valve body assembly.
When the resistance of the A/T fluid temperature sensor is outside the standard value, and the fluid temperature warning comes on/goes out at other than the specified temperatures, replace the valve body assembly and the harness.