SERVICE SPECIFICATIONS



Item
Standard value
CVT fluid temperature sensor resistance kΩ
at 0°C
Approximately 15.5
at 20°C
Approximately 6.5
at 40°C
Approximately 3.1
at 60°C
Approximately 1.6
at 80°C
Approximately 0.9
at 100°C
Approximately 0.5
Line pressure solenoid valve coil resistance (fluid temperature: 20°C) Ω
Approximately 5.6 - 6.6
Secondary pressure solenoid valve coil resistance (fluid temperature: 20°C) Ω
Approximately 5.6 - 6.6
Lockup/select switching solenoid valve coil resistance (fluid temperature: 20°C) Ω
Approximately 25.5 - 29.3
Lockup solenoid valve coil resistance (fluid temperature: 20°C) Ω
Approximately 5.6 - 6.6
Shift lock solenoid resistance Ω
24 ± 1.2
Engine stall speed r/min
D range
2,400 - 2,900
R range
2,400 - 2,900