Code No. P0741: Abnormality in Lock-up Function




DIAGNOSTIC FUNCTION


Abnormality is detected by the CVT-ECU when the torque converter slip speed is high during lockup control.

JUDGMENT CRITERIA


The status with the high torque converter slip speed continues for 30 seconds during lockup control (Primary pulley speed and engine speed are normal, and lockup differential pressure is 0.2 MPa or more).

PROBABLE CAUSES




DIAGNOSTIC PROCEDURE


STEP 1. Check other diagnosis codes.


Q. Are other diagnosis codes set?

Carry out the appropriate troubleshooting.
Go to Step 2.

STEP 2. M.U.T.-III data list



  • Item 07: Primary speed
  • Item 09: Engine speed
OK: No considerable difference is observed between the primary pulley speed and the engine speed.

Q. Is the check result normal?

Intermittent malfunction
Go to Step 3.

STEP 3. Line Pressure Check


Carry out "hydraulic test"(Refer to ).

Q. Is the check result normal?

Go to Step 4.
Repair according to the hydraulic pressure diagnosis table.

STEP 4. Symptom recheck after erasing diagnosis code


Q. Is the check result normal?

Intermittent malfunction
Replace CVT-ECU.