(1)Use the M.U.T.-III to bleed the air from the electric oil pump.(Refer to ).
|
|
(2)Item 62: Electric oil pump air bleeding status OK: "Completed" is displayed.
|
|
Q.
Is the check result normal?
|
|
The inspection is complete.
|
|
|
|
Use the M.U.T.-III to bleed the air from the electric oil pump (Refer to ).
During the air bleeding, check the electric oil pump drive sound and vibration.*
|
|
Q.
Is the check result normal?
|
|
Replace the electric oil pump. After that, bleed the air from the electric oil
pump (Refer to ).
|
|
|
|
Use the M.U.T.-III to bleed the air from the electric oil pump (Refer to ).
During the air bleeding, check the data list (secondary pressure).
|
|
- Item 19: Secondary pressure
|
|
Q.
Is the check result normal?
|
|
Complete the electric oil pump air bleeding (Refer to ).
The inspection is complete.
|
|
|
|
Remove the CVT sub oil strainer and visually check for clogs in the oil path.
|
|
Q.
Is the check result normal?
|
|
Replace the control sub-valve assembly. After that, bleed the air from the electric
oil pump (Refer to ).
|
|
|
|
Repair or replace the sub oil strainer. After that, bleed the air from the electric
oil pump (Refer to ).
|
|
|