DIAGNOSTIC FUNCTION



WARNING INDICATOR



<STANDARD METER>



If a malfunction occurs in the CVT system, any of "R", "N", "D", "Ds", "L" or "A" will flash (one flash per two seconds) on the selector lever position indicator in the multi-information display.
note
  • The selector lever position indicator "P" does not flash when a malfunction occurs in the CVT system.
  • When the system is normal, the selector lever position indicator "A" does not illumination. Only when a malfunction occurs in the indicator switch, the indicator will flash.
If the selector lever position indicator flashes rapidly (one flash per one second), the CVT fluid temperature is too high. (Illuminates when the fluid temperature is approximately 138°C or higher, and goes out automatically when the fluid temperature drops below approximately 135°C.)

<HIGH CONTRAST METER>



If a malfunction relating to the CVT system occurs, the symbol (A) will be displayed on the information screen in the multi-information display.
Check if the diagnosis code is set when the symbol (A) continues being displayed in the information screen in the multi information display.
When the symbol (B) is displayed in the information screen in the multi information display, the CVT fluid temperature is high. (Symbol (B) is turned on when the fluid temperature is approximately 138°C or higher and turned off automatically when the fluid temperature drops below approximately 135°C.)

HOW TO READ DIAGNOSIS CODE


Use M.U.T.-III to read the diagnosis code (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points ).

HOW TO ERASE DIAGNOSIS CODE


Use M.U.T.-III to erase the diagnosis code (Refer to GROUP 00 - How to Use Troubleshooting/Inspection Service Points ).