SOLENOID VALVE CHECK



1.While pressing A in the figure, turn B anti-clockwise to unlock the CVT assembly connector, and disconnect the connector.
2.Measure the resistance between the terminals of the applicable solenoid valves and the earth.
Standard value:
Terminal No.
Applicable solenoid valve
Resistance value Ω
1
Line pressure solenoid valve
Approximately 5.6 - 6.6 (fluid temperature: 20°C)
2
Secondary pressure solenoid valve
3
Lockup solenoid valve
4
Lockup/select switching solenoid valve
Approximately 25.5 - 29.3 (fluid temperature: 20°C)
3.When the resistance is within the standard value, check the power supply and the earth circuits.
4.
caution Each solenoid valve cannot be removed or replaced as a single unit. When replacement of any one of the solenoid valves is necessary, replace the valve body assembly.
When the resistance is outside the standard value, replace the valve body assembly and the harness.