DEAD LOCK RELAY INSPECTION <VEHICLES WITH DEAD LOCK SYSTEM>



Battery voltage
Tester connection
Specified condition
Not applied
3 - 4
Open circuit

  • Connect terminal No.1 and the positive battery terminal.
  • Connect terminal No.2 and the negative battery terminal.

3 - 4
Continuity exists (2 Ω or less)