DEAD LOCK RELAY INSPECTION <VEHICLES WITH DEAD LOCK SYSTEM>
Battery voltage
Tester connection
Specified condition
Not applied
3 - 4
Open circuit
Connect terminal No.1 and the positive battery terminal.
Connect terminal No.2 and the negative battery terminal.
3 - 4
Continuity exists (2 Ω or less)