Code No. B1648
Passenger’s air bag ON indicator lamp (open circuit)
caution
If the diagnosis code B1489 is set in the SRS-ECU,
be sure to diagnose the CAN bus line
OPERATION
Power for the passenger’s air bag ON indicator lamp is supplied
from the fusible link (2).
The passenger’s air bag ON indicator lamp illuminates when the ignition
switch is turned to the "ON" position and goes out after approximately 6 to 8 seconds if there
is not a malfunction in the SRS system.
TROUBLE JUDGEMENT
This code will be set if an open circuit has occurred in the wiring harness between the
passenger’s air bag ON indicator lamp and the SRS-ECU.
PROBABLE CAUSES
Damaged wiring harnesses or connectors
Malfunction of the SRS-ECU
Malfunction of the passenger’s air bag ON indicator lamp
DIAGNOSIS PROCEDURE
STEP 1. M.U.T.-III CAN bus diagnostics.
Use M.U.T.-III to diagnose the CAN bus lines.
Q.
Is the check result normal?
Go to Step 2.
Repair the CAN bus line (Refer to GROUP 54C - Troubleshooting ).
STEP 2. Check whether the diagnosis code is reset.
(1)Connect the negative battery terminal.
(2)After erasing the diagnosis code memory, check the diagnosis code again.
(3)Disconnect the negative battery terminal.
Q.
Is the diagnosis code No. B1648 set?
Go to Step 3.
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunction ).
STEP 3. Check the passenger’s air bag ON indicator lamp.
It is checked whether passenger’s air bag ON indicator lamp is normal (Refer
to ).
Q.
Is the check result normal?
Go to Step 4.
Replace hazard indicator assembly (Refer to GROUP 52A - Instrument Panel
Assembly ).
STEP 4. Resistance measurement at the SRS-ECU connector and the hazard
indicator assembly connector.
(1)Check that the negative battery terminal is disconnected. If the negative battery
terminal is connected, disconnect it.
(2)While pushing the part "A" indicated in the figure of the harness side connector, turn
the lock lever to the direction of the arrow to release the lock lever, and disconnect the SRS-ECU
connector. (3)Disconnect the hazard indicator assembly connector. (4)Take the measurements below at the SRS-ECU and hazard indicator assembly wiring
harness side connectors.
Continuity ONLP line between SRS-ECU connector and hazard
indicator assembly connector
OK: Continuity (less than 2 Ω)
Q.
Is the check result normal?
Go to Step 5.
Repair the wiring harnesses ONLP line between the SRS-ECU connector and the hazard
indicator assembly connector.
STEP 5. Measure the voltage at the centre panel assembly connector.
(1)Disconnect the hazard indicator assembly connector.
(2)Connect the negative battery terminal.
(3)Ignition switch: ON
(4)Measure the voltage between the hazard indicator assembly harness side connector
and the body earth. OK: System voltage
Q.
Is the check result normal?
Go to Step 6.
Repair the wiring harness IG+ line between the ETACS-ECU connector and
the hazard indicator assembly connector.
STEP 6. Check whether the diagnosis code is reset.
Q.
Is the diagnosis code No. B1648 set?
Replace SRS-ECU (Refer to ).
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunction ).