Code No.B2464 Meter information SW sticking <High contrast meter>


caution Before replacing the combination meter, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.


TROUBLE JUDGMENT


If the combination meter detects the meter information switch pressed state for 60 seconds or more continuously with the ignition switch at the ON position and the diagnosis code No. U1190 is not stored, the diagnosis code No. B2464 is stored.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Meter information switch check


Check the meter information switch. Refer to .

Q. Is the check result normal?

Go to Step 2.

Replace the meter information switch.

STEP 2. Resistance measurement at the meter information switch connector


(1)Disconnect the meter information switch connector, the measure at the harness side.
(2)Measure the resistance between the meter information switch connector (earth terminal) and the body earth.
OK: Continuity exists (2 Ω or less)

Q. Is the check result normal?

Go to Step 4.

Go to Step 3.

STEP 3. Check of open circuit (disconnect) in body earth line between meter information switch connector and body earth.


Q. Is the check result normal?

Go to Step 4.

Repair the connector(s) or wiring harness.

STEP 4. Check of short to power supply circuit (connect) in MODE line between combination meter connector and meter information switch connector.


Q. Is the check result normal?

Go to Step 5.

Repair the connector(s) or wiring harness.

STEP 5. Check whether the diagnosis code is reset.


Check again if the diagnosis code is set to the combination meter.
(1)Erase the diagnosis code.
(2)Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
(3)Check if diagnosis code is set.

Q. Is the diagnosis code set?

Replace the combination meter.

The diagnosis is complete.