If the diagnosis mode cannot be made an entry, the hands free-ECU, the communication between the hands free-ECU and the multivision display, or the power supply system of hands free-ECU may have a problem.
|
|
- The hands free-ECU may be defective.
- The multivision display may be defective.
- Damaged harness wires and connectors
|
|
Check if the multivision display work normally and the sound is output.
|
|
Q.
Is the check result normal?
|
|
Troubleshoot the multivision display. (Refer to .)
|
|
|
|
Q.
Is the check result normal?
|
|
Repair the connector(s) or wiring harness.
|
|
|
|
Perform the Inspection procedure 1 "Check the hands free-ECU power supply circuit." of the troubleshooting. (Refer to .)
|
|
Q.
Is the check result normal?
|
|
Repair according to the troubleshooting for reference.
|
|
|
|
Q.
Is the check result normal?
|
|
Replace the hands free-ECU.
|
|
|
|
Replace the multivision display.
|
|
|