Inspection Procedure 3: The hazard Warning lamps do not flash while the security alarm is triggered.



caution
  • Before replacing the ECU, ensure that the power supply circuit, the earth circuit and the communication circuit are normal.
  • When the ETACS-ECU of vehicles without KOS is replaced, the encrypted code of the ignition key needs to be registered to the ETACS-ECU. (If the encrypted code is not registered, the engine cannot be started. Register the encrypted code as described in Immobilizer System - How to Register Key ID .)

COMMENTS ON TROUBLE SYMPTOM


If the hazard warning lamps do not flash normally, the ETACS-ECU may be defective.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. Check that the hazard warning lamps operate.


Check that the hazard warning lamps illuminate normally.

Q. Is the check result normal?

Go to Step 2.

Troubleshoot the hazard warning lamps. Refer to Inspection Procedure 1 "The hazard warning lamps do not illuminate" .

STEP 2. M.U.T.-III diagnosis code


Check if diagnosis code is set to the ETACS-ECU.

Q. Is the diagnosis code set?

Troubleshoot the ETACS-ECU. Refer to .

Go to Step 3.

STEP 3. Retest the system


Check that the security alarm works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.