1.Remove the hazard indicator assembly. |
2.Connect the battery (+) terminal with the hazard indicator assembly connector terminal No. 13. Then, check if the security indicator is illuminated when the battery (-) terminal and the hazard indicator assembly connector terminal No. 17 are connected. |
3.If the security indicator is illuminated, it is judged good. |
|