REMOVAL AND INSTALLATION







Removal steps


1.
Bracket


2.
Oil filter bracket


3.
Gasket


4.
Bracket


5.
Connection


6.
O-ring
<<A>>
>>B<<
7.
Thermostat

>>A<<
8.
Oil sump


9.
Cylinder block

REMOVAL SERVICE POINT



<<A>> THERMOSTAT REMOVAL



1.Remove bolts of connecting flange, and remove connecting flange with thermostat.
2.Turn thermostat 1/4 turn (90°) to left and remove from connecting flange.

INSTALLATION SERVICE POINT



>>A<< OIL SUMP INSTALLATION


Apply sealant to oil sump, and then Install oil sump.
Specified sealant: Silicone sealant D 176 404 A2
note Clean sealing surface before fitting.

>>B<< THERMOSTAT INSTALLATION


note
  • Checking: Heat up thermostat in water.
  • Opening begins at approx. 85°C.
  • Ends at approx. 105°C.
  • Opening lift min. 7.0 mm.

1.Moisten new O-ring with coolant.
note Always renew seals and gaskets.
2.Insert thermostat into connecting flange and turn 1/4 turn (90°) to right.
note The brace on the thermostat must be almost vertical.
3.Fit connecting flange with thermostat into engine block.
4.Tighten securing bolts to the specified torque of 15 N·m.