Q.
Is the check result normal?
|
|
Repair or replace the connector.
|
|
|
|
- Disconnect connector, and measure at the harness side.
- Voltage between terminal No. 2 and earth.
|
|
Q.
Is the check result normal?
|
|
Q.
Is the check result normal?
|
|
Repair or replace the connector.
|
|
|
|
- Check earthing line for open circuit and damage.
|
|
Q.
Is the check result normal?
|
|
Repair the damaged harness wire.
|
|
|
|
Q.
Does trouble symptom persist?
|
|
Intermittent malfunction (Refer to GROUP 00 - How to Use Troubleshooting/Inspection
Service Points - How to Cope with Intermittent Malfunctions ).
|
|
|
|
- Disconnect connector, and measure at the harness side.
- Ignition switch: ON
- Voltage between terminal No. 1 and earth.
|
|
Q.
Is the check result normal?
|
|
- Disconnect engine-ECU connector, and connect special tool power plant ECU
check harness (MB992044) to measure at connector for inspection.
- Disconnect B-11 fuel temperature sensor connector.
- Ignition switch: ON
- Voltage between terminal No. 24 and earth.
|
|
Q.
Is the check result normal?
|
|
Q.
Is the check result normal?
|
|
Check and repair harness between B-11 (terminal
No. 1) fuel temperature sensor connector and B-05 (terminal No. 24) engine-ECU connector.
- Check output line for open circuit.
|
|
|
|
Repair or replace the connector.
|
|
|
|
Q.
Is the check result normal?
|
|
Repair or replace the connector.
|
|
|
|
- Check output line for short circuit.
|
|
Q.
Is the check result normal?
|
|
Repair the damaged harness wire.
|
|
|
|
Q.
Is the check result normal?
|
|
Repair or replace the connector.
|
|
|
|
- Check output line for damage.
|
|
Q.
Is the check result normal?
|
|
Repair or replace the connector.
|
|
|
|
- After replacing the fuel temperature sensor, re-check the trouble symptoms.
|
|
Q.
Does trouble symptom persist?
|