WCM sets the diagnosis code No. B1A24 when the key ID was not registered in it.
JUDGEMENT CRITERIA
WCM determines that the abnormality is present, if the ignition key’s key ID
is not registered in WCM when the ignition switch is turned ON.
PROBABLE CAUSES
Key ID not registered
Malfunction of the ignition key
Malfunction of WCM
DIAGNOSIS PROCEDURE
STEP 1. Register the key ID and recheck the diagnosis
code.
Register the key ID of the ignition key by which the diagnosis code is set (Refer to ),
and recheck if the diagnosis code is set.
(1)Turn the ignition switch from the LOCK (OFF) position to the ON position.
(2)Check if the diagnosis code is set.
Q.
Is the diagnosis code set?
Go to Step 2.
The diagnosis is complete.
STEP 2. Replace the ignition key and recheck the diagnosis code.
Replace the ignition key by which the diagnosis code is set with a new one, register the
key ID of the new key, (Refer to ), and recheck if the diagnosis
code is set.
(1)Turn the ignition switch from the LOCK (OFF) position to the ON position.
(2)Check if the diagnosis code is set.
Q.
Is the diagnosis code set?
Replace WCM and register the ID codes (Refer to ).