Inspection Procedure 13: The Comfort Flashing Function does not Work Normally.




COMMENTS ON TROUBLE SYMPTOM


If the comfort flashing function does not work normally, the turn-signal lamp switch input circuit(s) and ETACS-ECU may have a problem.

PROBABLE CAUSES




DIAGNOSIS PROCEDURE


STEP 1. ETACS-ECU customise function check


Use the ETACS-ECU customise function to check that the "Comfort flasher" is set to "Enable."

Q. Is the check result normal?

Go to Step 2.

Use the ETACS-ECU customise function to set the "Comfort flasher" to "Enable" (Refer to ).

STEP 2. M.U.T.-III diagnosis code


Check if diagnosis code is set to the ETACS-ECU.

Q. Is the diagnosis code set?

Troubleshoot the ETACS-ECU. Refer to .

Go to Step 3.

STEP 3. Check that the turn-signal lamps operate.


Check that the turn-signal lamps work normally when the ignition switch is in the ON position.

Q. Is the check result normal?

Go to Step 4.

Refer to Inspection Procedure 12 "The turn-signal lamps do not illuminate" .

STEP 4. Retest the system


Check that the comfort flashing function works normally.

Q. Is the check result normal?

The trouble can be an intermittent malfunction (Refer to GROUP 00 - How to use Troubleshooting/inspection Service Points - How to Cope with Intermittent Malfunction ).

Replace the ETACS-ECU.