Code No.B2467 Malfunction of stepper motor




TROUBLE JUDGMENT


With the ignition switch at the ON position and the system voltage at 10-16 V (data from ETACS-ECU), if the combination meter detects the stepper motor malfunction, diagnosis code No. B2467 is stored.

PROBABLE CAUSES


Malfunction of combination meter

DIAGNOSIS PROCEDURE


Check whether the diagnosis code is reset.


Check again if the diagnosis code is set to the combination meter.
(1)Erase the diagnosis code.
(2)Turn the ignition switch from "LOCK" (OFF) position to "ON" position.
(3)Check if diagnosis code is set.

Q. Is the diagnosis code set?

Replace the combination meter.

The diagnosis is complete.