INSPECTION



REFRIGERANT TEMPERATURE SWITCH



1.
caution Do not heat than necessary.
Immerse the refrigerant temperature sensor probe into engine oil to heat the sensor probe.

2.If the oil temperature reaches the standard value, there should be continuity between the switch terminals.
Standard value:
Switch status
Operating temperature °C
Being turned off (No continuity)
155
Being turned on [Continuity exists (2 Ω or less)]
125