Code No.
|
Diagnostic item
|
Reference page
|
Service data display contents when diagnosis code is set
|
B1034 (set by A/C-ECU)
|
Interior temperature sensor system (short circuit)
|
|
25°C
|
B1035 (set by A/C-ECU)
|
Interior temperature sensor system (open circuit)
|
B1034 (set by ETACS-ECU)
|
Ambient air temperature sensor system (short circuit)
|
|
20°C
|
B1035 (set by ETACS-ECU)
|
Ambient air temperature sensor system (open circuit)
|
B1031
|
Air thermo sensor system (short circuit)
|
|
Air recirculation position: Interior temperature Fresh air position: Fresh air +
10°C
|
B1032
|
Air thermo sensor system (open circuit)
|
B1000
|
Control panel communication error
|
|
-
|
B1018
|
Temperature adjusting SW
|
|
-
|
B1003
|
Mode changeover SW
|
|
-
|
B1021
|
Blower fan SW
|
|
-
|
B1079
|
A/C refrigerant leaks
|
|
-
|
B2214
|
Control panel failure
|
|
-
|
B222C
|
Coding incomplete
|
|
-
|
B223B
|
Control panel improperly assembled
|
|
-
|
U0019
|
Bus off (CAN-B)
|
|
-
|
U0141
|
ETACS-ECU CAN time-out
|
|
-
|
U0151
|
SRS CAN time-out
|
|
-
|
U0155
|
Meter CAN time-out
|
|
-
|
U0168
|
WCM CAN time-out
|
|
-
|
U0184
|
Audio CAN time-out
|
|
-
|