Code No. B1079: Refrigerant leaks






COMMENTS ON TROUBLE SYMPTOM


If this code is set, the refrigerant level may not be appropriate, or the A/C pressure sensor may be faulty (If this code is set, the A/C indicator will flash).

PROBABLE CAUSES



  • Inadequate refrigerant level
  • Malfunction of the A/C pressure sensor
  • Malfunction of the ambient temperature sensor
  • Damaged the wiring harness or connectors
  • Malfunction of the A/C-ECU

DIAGNOSIS PROCEDURE


STEP 1. Check the condenser assembly


Check that the condenser assembly is not wet.

Q. Is the check result normal?

Go to Step 2.
Wait until the condenser is dry, and check that no diagnosis code is set.

STEP 2. M.U.T.-III CAN bus diagnostics


Use the M.U.T.-III to diagnose the CAN bus lines.

Q. Is the check result normal?

Go to Step 3.
Repair the CAN bus lines. (Refer to GROUP 54C, Troubleshooting ).

STEP 3. M.U.T.-III diagnosis code


Check that the diagnosis code related to the A/C is not set.

Q. Is the diagnosis code set?

Carry out the diagnosis code procedures. Refer to .
Go to Step 4.

STEP 4. M.U.T.-III data list


Check that the following service data display contents are normal. (Refer to )

  • Item 02: Ambient temperature sensor

Q. Is the check result normal?

Go to Step 5.
Refer to code No.B1011, B1012: Ambient temperature sensor system .

STEP 5. Check the A/C pressure sensor


Refer to .

Q. Is the check result normal?

Go to Step 6.
Replace the A/C pressure sensor.

STEP 6. Refrigerant level check


Refer to .

Q. Is the check result normal?

Go to Step 7.
Correct the refrigerant level.

STEP 7. Check whether the diagnosis code is reset


Q. Is the diagnosis code set?

Refer to Inspection Procedure 12: A/C pressure sensor system .
The trouble can be an intermittent malfunction (Refer to GROUP 00, How to Cope with Intermittent Malfunction ).