1.Before inspection, set the vehicle to the pre-inspection condition. 2.Turn the ignition switch to "LOCK" (OFF) position. 3.Connect the M.U.T.-III to the diagnosis connector.
|
|
4.Disconnect the ventilation hose from the positive crankcase ventilation (PVC) valve, and
then connect a vacuum gauge to the ventilation hose. Plug the PCV valve. 5.Start the engine and check that idle speed is approximately 700 r/min. 6.Check the intake manifold vacuum. Limit: Minimum 60 kPa 7.Turn off the ignition switch. 8.Remove the vacuum gauge and then connect the ventilation hose to the PCV valve. 9.Disconnect the M.U.T.-III.
|