INHIBITOR SWITCH AND CONTROL CABLE ADJUSTMENT


1.Set the selector lever to the "N" position.

2.Loosen the control cable to the manual control lever adjusting nut to free the cable and lever.
3.Set the manual control lever to the neutral position.

4.Loosen the inhibitor switch body mounting bolts and turn the inhibitor switch body so the hole in the end of the manual control lever and the hole (section A - A in the figure on the left) in the flange of the inhibitor switch body flange are aligned.
note The inhibitor switch body can be aligned by inserting a 5-mm diameter steel bar into the end hole of the manual control lever and the flange hole of the inhibitor switch body.
5.Tighten the inhibitor switch body mounting bolts to the specified torque. Be careful at this time that the switch body does not move.
Tightening torque: 5.9 ± 1.0 N·m

6.Tighten the transmission control cable using the adjusting nut with the specified torque.
Tightening torque: 9.5 ± 3.5 N·m
7.Check that the selector lever is in the N position.
8.Check that each position of the manual control lever matches each position of the selector lever using M.U.T.-III MB991958 (M.U.T.-III sub assembly).