ALTERNATOR AND OTHERS BELT TENSION CHECK


1.Remove the radiator condenser tank mounting bolts.
2.Move the radiator condenser tank to a place where it will not be a hindrance when checking the alternator and others belt tension.

3.
caution Check the alternator and others belt tension after turning the crankshaft clockwise one turn or more.
Make sure that the indicator mark on the alternator drive belt auto-tensioner is within the area marked with A in the illustration.
4.If the mark is out of the area A, replace the alternator and others belt (Refer to ).
note The alternator and others belt tension check is not necessary as the alternator drive belt auto-tensioner is adopted.
5.Tighten the radiator condenser tank mounting bolts to the specified torque.
Tightening torque: 12 ± 2 N·m