DOOR LOCK










DESCRIPTION OF STRUCTURE AND OPERATION



CENTRAL DOOR LOCKING




KEY REMINDER FUNCTION




When the driver’s door is opened with the ignition key inserted to the ignition cylinder and the door is locked, after approximately 0.3 second, ETACS-ECU turns ON the unlock relay output for 0.25 second to discourage the door lock operation so that the ignition key left in the ignition cylinder is prevented. If the discouraging the door lock operation fails, the current supply will be retried (The unlock relay output is turned ON for 0.25 second up to five times with one second interval).
note The broken line in the graph indicates the current supply retry state if the discouraging door lock operation fails.