Measure the resistance between the following solenoid valve terminals.
- Control solenoid valve IN (FR): Between terminals (19) -
(34)
- Control solenoid valve OUT (FR): Between terminals (20) -
(34)
- Control solenoid valve IN (FL): Between terminals (21) -
(34)
- Control solenoid valve OUT (FL): Between terminals (22) -
(34)
- Control solenoid valve IN (RR): Between terminals (15) -
(34)
- Control solenoid valve OUT (RR): Between terminals (16) -
(34)
- Control solenoid valve IN (RL): Between terminals (13) -
(34)
- Control solenoid valve OUT (RL): Between terminals (14) -
(34)
- Select solenoid valve (SA1): Between terminals (18) -
(34)
- Select solenoid valve (SA2): Between terminals (17) -
(34)
- Select solenoid valve (SA3): Between terminals (12) -
(34)
- Select solenoid valve (STR): Between terminals (11) -
(34)
Standard value:
Control solenoid valve IN: 4.75 -
5.25 Ω Control solenoid valve OUT: 2.0 -
2.4 Ω Select solenoid valve: 3.5 -
3.9 Ω
|