SOLENOID VALVE CHECK



Measure the resistance between the following solenoid valve terminals.

  • Control solenoid valve IN (FR): Between terminals (19) - (34)
  • Control solenoid valve OUT (FR): Between terminals (20) - (34)
  • Control solenoid valve IN (FL): Between terminals (21) - (34)
  • Control solenoid valve OUT (FL): Between terminals (22) - (34)
  • Control solenoid valve IN (RR): Between terminals (15) - (34)
  • Control solenoid valve OUT (RR): Between terminals (16) - (34)
  • Control solenoid valve IN (RL): Between terminals (13) - (34)
  • Control solenoid valve OUT (RL): Between terminals (14) - (34)
  • Select solenoid valve (SA1): Between terminals (18) - (34)
  • Select solenoid valve (SA2): Between terminals (17) - (34)
  • Select solenoid valve (SA3): Between terminals (12) - (34)
  • Select solenoid valve (STR): Between terminals (11) - (34)
Standard value:
    Control solenoid valve IN: 4.75 - 5.25 Ω
    Control solenoid valve OUT: 2.0 - 2.4 Ω
    Select solenoid valve: 3.5 - 3.9 Ω